FELIX BURGLER ALARM SYSTEM PROGRAMMING MANAUL
1.
ALL ZONES ARM
Press F1 (extreme right top key)
2. ALL ZONES DISARM
User Password (default: 123456) + F4 (extreme right down key)
3.INDIVIDUAL
ZONE ARM
Press zone number + F1
(eg: arm first zone 01+F1)
4.INDIVIDUAL
ZONE DISARM
User password + F4
5.TIME
BASED ARM AND DISARM
Press 46 + HH (hour) + MM (minute) + F4
Press 47 + HH + MM + F4 (Disarm)
6. REMOTE CONTROL ON
Program Password + 71 +
1 +
F4
7. REMOTE CONTROL OFF
Program Password (default: 666666) + 71 + 1 + F4
(Note: coming out from the program mode isà * #
(Star Hash))
8. HOW TO PROGRAM TELEPHONE NUMBER
Program Password + 5 + Group number + tele number + F4
(Note: coming out from the program mode isà * # (Star Hash))
(eg: setup first groupàPress 5 + 1 + 0988888888 + F4)
9. Register Wireless Detector
Program Password + 20 + zone number + F4 + Procedure + F4
(Procedure: press the button
inside the detector. That time SINGAL LED will be ON in the keypad)
(Note: coming out from the program mode isà * # (Star Hash))
10. SETTING ARM
DEAY TIME
Program Password + 40 + Time + F4
(Time: 000 to 255 Seconds)
10. SETTING DIS- ARM DEAY TIME
Program Password + 0131 + 43 + TIME
(Time: 000 to 255 Seconds)
Setting Panic Button for 24Hours trigger in Disarm
condition:
“666666 + 16 (zone)+2 (zone type) +1 (Siren on/off)+F4” then
"666666 + 20 + 16 + F4 + press button in panic button or any sensor +
F4"
11. REMOTE
CONTROL ARM WITH TELEPHONE
Call to the telephone
number, which has connected to the alarm system.
While get through, dial
user password (default: 123456) you can hear long beep, then dial 1.if u can hear the long beep, its arm
successfully. If you hear error beep (three short beep) indicates fault.
12. CHANGE USER PASSWORD
User password + 08 + F4, (“ SET ”
led will be ON)
+ Dial
new password + F4
13. RESET
SYSTEM
951753082 + F4